Why An OTDR Shows Negative Splice Loss: Bidirectional Testing

What causes a gainer

Fibers on either side of a fusion splice may return different amounts of backscattered light. An OTDR estimates event loss from that returned signal. A change in backscatter can make the same splice appear to gain power in one direction and lose more power in the other. Mixed-fiber builds are a good reason to retain the fiber type and manufacturer’s mode field diameter information.

Pair the same splice before averaging

Capture both A-to-B and B-to-A traces for the same fiber and wavelength. Use the fiber ID and splice plan to pair the same physical event. Its distance from the instrument changes when the instrument moves to the other end. For example, if the paired readings are −0.20 dB and +0.40 dB, their average is 0.10 dB. The example illustrates the calculation. Use the project’s specified acceptance limit.

Keep an auditable record

Retain both raw traces and record the wavelength, splice ID and averaged result. Investigate events that are hidden, outside the measurement boundary or ambiguous to match before accepting the splice. A single negative-loss reading is insufficient evidence for reworking a splice.