Home | My Wish List | Compare Products | Advised Products | Vendors | Bank Accounts | News | FAQ | Advice | Contact
19" FLOOR STANDING RACKS 19" WALL MOUNTED CABINETS 19'' ACCESSORIES FIBER OPTIC SOLUTIONS COPPER CABLING SOLUTIONS REMOTE CONTROL SYSTEMS POWER SOLUTIONS CONTRACT MANUFACTURING BARGAIN SHOP
 Categories
19" FLOOR STANDING RACKS
19" WALL MOUNTED CABINETS
19'' ACCESSORIES
FIBER OPTIC SOLUTIONS
COPPER CABLING SOLUTIONS
REMOTE CONTROL SYSTEMS
POWER SOLUTIONS
CONTRACT MANUFACTURING
BARGAIN SHOP
 Links
About Us - Hakkımızda...
Sales Terms & Conditions...
SKY CONTROL SOLUTIONS...
Mail Order Form...
 Support
Phone

+90 216 371 53 33

 Newsletter
Add Remove
 Your Opinion
How did you find this web site?
word of mouth
search engine
banner ad
friend
other
View all polls »

« Back  All Records »

SKY CONTROL SOLUTIONS

MONITORING SYSTEMS

Monitoring system of automatic control of remote communication units, telecommunication objects, towers, boards of command, single shops, storage facilities, offices and other objects where it is unprofitable to maintain constant security staff. 

Required items:

  • Master unit of type 55хх.824
  • Several sensors of physical parameters.
  • Fans, cooling devices, heaters and etc.
  • Web-camera
  • LAN network or GPRS

Sensors are connected to master unit's inputs, objects of power supply are connected to the relay, Web-camera is connected to master unit's USB input. Output LAN is connected to any external network, if its not present, LAN is connected to built-in GPRS modem.

System logic is adjusted in such way that at an increase or reduction of temperature, variation of other sensors' readings, the contacts switch on and power supply from corresponding relay contacts is given to objects of power supply.

As a result, the system will automatically trace processes inside the premises or in a telecommunication rack, and counteract them. For instance, at rise in temperature in certain point, the cooling fan switches on. 



REMOTE POWER MANAGEMENT SYSTEM

Remote power management of servers and other objects of power supply.

For realization of this system it is required:

  • Any Monitoring master unit.
  • As an extension — any Master unit that controls either outlets or relay outputs.

Depending on quantity of remotely operated sockets, corresponding types of units are selected. 

The screen of administrator's web-control panel shows data about presence of voltage on each socket and if version of unit permits, size of the current going through the outlet.  Administrator may be able to set a current clamp, logic of automatic or manual switching on/off separate sockets or a specific socket strip.

In such system any other expansion units can be connected, allowing to monitor various sensors of temperature, humidity, gas, radiation, water, pressure and etc. as well as input readers controlling access to an object.

ACCESS SYSTEM

System requires:

  • Any monitoring master unit.
  • Access readers iButton or Proximity, connected to digital input RJ-9 using UTP cable.  Each input needs a separate reader!
  • Several Proximity cards or iButton keys.

All iButton keys have unique identifier, in the same way as Proximity cards. 

It is possible to use input readers and keys iButton and Proximity simultaneously in one access system provided there is sufficient quantity of digital inputs on units.

System allows to easily add new keys or cards to database of authorized persons by a simple touch to the input reader. 

System stores data about entries in the system log, which has several filters (by name or time), and which allows to quickly find data on access of a certain user.

SURVEILLANCE SYSTEM

Any monitoring unit can be used as surveillance device and as alarm system in an apartment, house, office or any other premises. For realization of this system it is required:

  • Monitoring master unit.
  • Several non-contact sensors of open door (depending on quantity of door entries).
  • Several vibration sensors (depending on quantity of windows inside the premise), if the considered building is on the ground floor.
  • Smoke sensors. Several sensors are needed for reduction of false alarm possibility.
  • USB web-camera.
  • Alarm, firefighting system.

Sensors are connected to master unit's inputs. Web-camera is connected to USB input. At alarm and firefighting systems' power cut, operating contact of the relay is connected. The system logic is adjusted in such way that at initiation of certain sensors, observers receive notifications, if after a while no measures are taken and situation has not changed, USB web-camera switches on and pictures are transferred to the remote server. Alternatively, an operating contact and voltage is given to alarm or signal is given to firefighting system.


APPLICATION OF CONNECTING RELAY-SENSOR MODULES

Functions of the system described above can be expanded by connecting additional modules.  These modules allow to increase quantity of connected sensors and relay to one system and to increase functioning range.  Necessity in such device can arise, for example, in a remote building or office with several floors.  Required:

  • Additional relay-sensor expansion module.
  • Several sensors of physical parameters, such as temperature sensor, humidity, pressure, contact sensor.
  • Fans, cooling devices, heaters, etc.
  • Smoke sensors.  Several sensors necessary for reduction of probability of false operation.
  • If necessary leakage sensors, gas, voltage sensors. 
  • Siren, fire-fighting systems. 
  • Connection to Internet.

Sensors are connected to modules' inputs, power consumers (fans, coolers etc) are connected to relay connectors of modules. The system will automatically trace processes in a given premise or in a telecommunication rack, distinguish them and automatically warn and carry out actions registered in logic, for example send notifications to the administrator. Temperature and humidity sensors can be embedded in the module.



APPLICATION OF CONNECTING ADDRESS CONTACTS MODULES

Needed when there is a necessity of address tracking of doors and windows status, buttons and reed switches of type «opened-closed». Conventional contact sensors can be consistently installed in system of monitoring, however, it would not be possible to track which door exactly was opened or closed. For address definition of a condition of doors or windows the following are required:

  • Additional address contacts module 5505.016.  
  • Two-wire cable, power and network cables.

Module automatically traces condition of contacts, distinguishes them and automatically contacts system module, informing on change  of contacts status that will allow system to warn and carry out actions registered in logic, for example to start a siren,  to send notifications to the administrator, or to initiate protecting arrangements.  Module includes built-in temperature sensor.

15 Haziran 2008 Pazar  Views : 18545

  Membership Panel
Mail
Password
Create a new account
Forgot my password




  My Cart
Your shopping cart is currently empty

  News
Sky control monitoring system can now send images and video from connected web-camera via e-mail. All you need is just setup logic.

Sky control monitoring system can now send images and video from connected web-camera via e-mail. Al...»

We are currently adding our portfolio to this website

We are currently adding our portfolio to this website  ...»

  Advised Products
42U 800X800 19'' FLOOR STANDING NETWORK RACK
42U 800x800 19'' FLOOR STANDING NETWORK RACK

Home | About Us - Hakkımızda | Sales Terms & Conditions | SKY CONTROL SOLUTIONS | Mail Order Form | Contact